Listing the error codes in the range from 8000 to 8999. These are SRCI app custom alarms.
v1.1.0
Listing the error codes in the range from 8000 to 8999. These are SRCI app custom alarms.
v1.1.0
Description:
The SRCI function is inexistent.
Context:
Can occur during startup only.
Remedy:
Update the system software of the controller (YRC1000: >= 4.90).
Description:
The SRCI function is unlicensed.
Context:
Can occur during startup only.
Remedy:
Contact Yaskawa to purchase the unlicensed function for the controller.
Description:
The SRCI function is disabled.
Context:
Can occur during startup only.
Remedy:
Enable the function in maintenance mode of the controller.
Description:
The ethernet function is unlicensed.
Context:
Can occur during startup only.
Remedy:
Contact Yaskawa to purchase the unlicensed function for the controller.
Description:
The FTP function is disabled.
Context:
Can occur during startup only.
Remedy:
Enable the function in maintenance mode of the controller.
Description:
The FTP function is restricted.
Context:
Can occur during startup only.
Remedy:
Change the FTP function (Level to “STANDARD”; Parameter RS5 to 1;
Parameter RS7 to 2).
Description:
The MotoLogix function is unlicensed.
Context:
Can occur during startup only.
Remedy:
Contact Yaskawa to purchase the unlicensed function for the controller.
Description:
The MotoLogix function is disabled.
Context:
Can occur during startup only.
Remedy:
Enable the function in maintenance mode of the controller.
Description:
The MotoLogix function endianness setting is incorrect
Context:
Can occur during startup only.
Remedy:
Change the endianness in MotoLogix setup to little.
Description:
The network connection to the PLC is lost.
Context:
Can occur after startup only.
Remedy:
Check the network connection to the PLC.
Description:
The network life sign timed out.
Context:
Can occur after startup only.
Remedy:
Adapt the network load to the timeout or adapt the timeout to the network
load.
Description:
The sequence timed out.
Context:
Can occur after startup only.
Remedy:
Reduce the amount of requests from the PLC to the controller.
Description:
The operation mode “remote” is required.
Context:
Can occur after operator interaction (including startup) only.
Remedy:
Switch the operation mode to remote.
Description:
User data status update failed.
Context:
Can occur after operator interaction (including startup) only.
Remedy:
Clear the alarm and switch the operation mode to teach and back to
remote.
Description:
Create controller default user frame failed.
Context:
Can occur after operator interaction (including startup) only.
Remedy:
Clear the alarm and switch the operation mode to teach and back to
remote.
Description:
Internal error occurred (Log on USB storage at controller).
Context:
Can occur at any time.
Remedy:
Connect a FAT formatted USB storage to the USB port of the controller and
retry the failed operation. If the operation fails again, log files named
srci_panic_log.txt
and/or YRP_LOG.txt
will be written to the USB
storage. Please provide a description of the failed operation and the log
files to Yaskawa.
Description:
Internal error occurred (Log unavailable).
Context:
Can occur at any time.
Remedy:
Please provide a description of the failed operation and the alarm message
to Yaskawa.